Item # S-70019-001, FR-C2A1 Cartridge

Cartridges >> Item # S-70019-001, FR-C2A1 Cartridge

Inquire about this Product

    Check all that apply
  • What category best describes your organization?
  • This field is for validation purposes and should be left unchanged.

  • Shelf Life5 Years (polybag) – Other Packaging Available
  • Diameter4.23 in
    107 mm
  • Overall Height3.0 in
    76 mm
  • Approx. Weight9 oz
    255 g
  • ConnectionEN 148-1 (40mm) NATO thread
  • Body MaterialNoryl® GFN1
  • Pressure Drop40 mm H2O (nominal) measured at NIOSH airflow rate of 85 lpm
  • ProtectionsNIOSH-Approved Protection meeting/exceeding 42 CFR Part 84 requirements:
    Particulates (APR) –P100
    Particulates (PAPR) – HE
    Chlorine – (CL)
    Hydrogen Chloride – (HC)
    Sulfur Dioxide – (SD)
    o-Chlorobenzylidene malononitrile – (CS Tear Gas)
    α-Chloroacetophenone – (CN Tear Gas)
    Military Chemical Warfare Agent (CWA) Protection:
    Chloropicrin – (PS)
    Cyanogen Chloride – (CK)
    Dimethyl Methylphosphonate – (DMMP)
    Hydrogen Cyanide – (AC)
    Phosgene – (CG)
    Sarin – (GB)
  • NIOSH Approved Configuration with the IRT FR-C2A1 Cartridge
    NIOSH Approval No. Protections Description
    TC-23C-2469 HE/CL/HC/SD/CS/CN C420 PAPR w/Promask 2000 Full Facepiece (Positive Pressure)
    TC-23C-2485 HE/CL/HC/SD/CS/CN C420 PAPR w/M95 Full Facepiece (Positive Pressure)
    TC-84A-5040 P100/CL/HC/SD/CS/CN Promask 2000 Full Facepiece (Negative Pressure)
    TC-84A-5193 P100/CL/HC/SD/CS/CN M95 Full Facepiece (Negative Pressure)

  • IRT FR-C2A1 Cartridge Exceeds Gas Service Life Requirements Specified In 42 CFR Part 84
    Gas/Vapor Challenge Formula Test Concentration (ppm) Breakthrough Concentration (ppm) Exceeds NIOSH 42 CFR Part 84 Minimum Service Life Rqmts
    APR Service Life Rqmts (in minutes) PAPR Service Life Rqmts As received (in minutes) PAPR Service Life Rqmts Equilibrated (in minutes)
    Chlorine (CL) Cl2 500 5 17.5 17.5 8.7
    Hydrogen Chloride (HC) HCl 500 5 25 25 12.5
    Sulfur Dioxide (SD) SO2 500 5 15 15 7.5
    o-Chlorobenzylidene malononitrile (CS) ClC6H4CH=C (CN)2 3 0.05 480 480 480
    a-Chloroacetophenone (CN) C6H5COCH2Cl 16 0.05 480 480 480

  • IRT FR-C2A1 Cartridge Exceeds Military Chemical Warfare Agent Requirements1
    Gas Challenge Test Concentration (mg/m3) Test Flow Rate (lpm) Testing Relative Humidity (%) Breakthrough Concentration (mg/m3) Minimum Required Service Life Time (in minutes)
    Chloropicrin (PS)2 5000 30 80 5 27
    Cyanogen Chloride (CK)3 4000 32 80 8 30
    Cyanogen Chloride (CK)4 4000 30 80 5 55
    Cyanogen 8Chloride (CK) – Aged4 4000 30 80 5 45
    Dimethyl Methylphosphonate (DMMP)3, 5 3,000 50 50 0.04 59
    Dimethyl Methylphosphonate (DMMP)4, 5 3,000 30 ≤15 0.04 175
    Hydrogen Cyanide (AC)4 4000 32 80 5 28
    Phosgene (CG)4 20000 32 80 8 25
    Sarin (GB)3 4000 32 ≤15 0.04 83

    Notes:

    1. There are no NIOSH approval protocols for testing chemical warfare agents in accordance with the requirement referenced in note 2 thru 4 below.
    2. Cartridge gas service life testing in accordance with QSTAG 295, Second Draft.
    3. Cartridge gas service life testing in accordance with MIL-PRF-51560C.
    4. Carbon gas service life testing in accordance with MIL-DTL-32101A.
    5. Dimethyl Methylphosphonate is a surrogate test agent for Sarin.

    ITAR WARNING: This product is controlled by the U.S. Munitions List and International Traffic in Arms Regulations. U.S. State Department authority for export from the United States is required. Re-export, re-transfer, or disclosure to unauthorized parties, including non-US Persons is prohibited.